The C 2000 Calorimeter
MADE in the USA
Engineered in Germany

A high level of automation with extremely simple handling characterizes this instrument. In addition to the isoperibol measurement procedure (static jacket), a dynamic (reduced-time) working method is also available.

There are two Versions of the Calorimeter available. Version 1 includes the standard decomposition vessel C 5010 (see “Accessories”) and Version 2 includes the halogen resistant and catalytic activated decomposition vessel C 5012 (see “Accessories”).

To provide the calorimeter with cooling water, it needs to be connected to a thermostat i.e. cooling water supply KV 600 or a firmly installed water connection using the C 25 Water pressure regulating valve (see “Accessories”).

Since the handling of the unit is most convenient by using the cooling water supply KV 600, we have created an exclusive Package for the US-Market that already includes it. These Packages can not be found on the internet. The item numbers and descriptions are:

8801891
C 2000 basic Version 1 Package (115V)

8801991
C 2000 basic Version 2 Package (115V)
8801890
C 2000 basic Version 1 Package (230V)

8801990
C 2000 basic Version 2 Package (230V)

The Calorimeter is equipped with a very convenient console to operate the unit. All settings and necessary experiment parameters including special required ASTM or DIN calculations can be done through this console.

Very important for the customers of the US-Market is, that an instrument is easy to service, and maintenance can be done fast. Many customers have their own in-house engineers that take care of the analytical equipment. Caused by the great size of the North American continent, it is not cost and time effective to send units through the country. This is why IKA has developed the C 2000 especially for this Market. The unit is composed of modules. If one fails, it can easily be replaced. This minimizes the down-time of a unit very drastically. More than 95% of our Service on Calorimeters is handled over the phone with an engineer of the customer.

The automatic water handling system handles the tempering, filling and emptying of calorimeter inner- and outer vessel.

Oxygen is filled into the decomposition vessel automatically
.
The decomposition vessel is identified automatically as well. This reduces the possibility of handling errors.

As soon as the unit is ready to ignite the sample, it will initiate it automatically.

Several interface connections allow the unit to be connected with a balance/scale, printer, monitor, keyboard, sample rack C 5020 and a PC or laptop.

Even the integration into a LIMS is no Problem at all for the IKA Calorimeters. We provide the RS 232 protocol, and the signals can easily be adjusted to the customers LIMS.

There are 2 different measurement modes available. Depending on the purpose the user can choose the best mode for his individual application.

Mode Measurement time Comments
Isoperibol approx. 22 min Works according to standards
Dynamic approx. 7 min Time reduced, isoperibol measurement

Upgrading the system? No Problem !
Scope of supply (C 2000)

8801891 C 2000 basic Version 1 Package (115V)
Consisting of:  
3180001 C 2000 basic Calorimeter (115V)
7114000 C 5010 Decomposition vessel, standard
3410501 KV 600 Cooling water supply (115V)

The following parts are included with the delivery of each unit

C 710.4 Cotton threads (500 pieces)
Last for 500 ignitions / experiments
C 723 Benzoic acid (50 Tablets each 0.5)
Last for up to 25 calibrations with each 1g Benzoic acid
Spare ignition wire
Depending on the type of vessel and/or sample used, each wire can be used for 50 to 100 combustions.
C 5003.1 Aqua Pro
Needed to adjust the conductivity of the water inside the unit and prevents fast growth of Algae
Venting tool
To vent the gas from the decomposition vessel after the experiment